Wanty 0.018'' OTW PTA Balloon Dilatation Catheter

Wanty 0.018'' OTW PTA Balloon Dilatation Catheter

0.018" PTA balloon dilatation catheter The main force of lower extremity ASO balloon 1. 4-5F Small Outer Diameter Vascular Sheath Compatibility2. 2-9 mm diameter, 20-220 mm balloon length3. 90, 130, 180cm catheter lengths4. Rated burst pressure(RBP) up to 16 atm

Introdução de Produto

Description 

  • O Cateter Balão WANTY PTA é um cateter balão periférico over the wire (OTW), projetado especificamente para angioplastia transluminal percutânea em vasos ateroscleróticos obstruídos.

  • O revestimento hidrofílico que cobre a extremidade distal do cateter proporciona uma lubrificação melhorada ao eixo do balão.

  • A guidewire ({{0}}.014" 0.018" 0.035") is recommended for use with the Balloon Catheter (Balloon catheter specification refers to the attachment for detailed). The connector(s) at the end of hub provide two accuracy conical fittings with a 6 percent luer taper for securely fitted to other medicalequipment.


Intened use 

Os Cateteres Balão WANTY PTA são indicados para angioplastia transluminal periférica (PTA) para sistema vascular periférico (incluindo artéria ilíaca, artéria femoral, artéria ilíaca femoral, artéria poplítea e artéria genicular inferior). diâmetro calculado para o tratamento da doença obstrutiva das artérias periféricas.

image

Especificações do modelo



Doença

PTA Balloon Catheter

Model Specifications

Iliac artery stenosis

Common iliac artery:7-10mm; external iliac artery:5-8mm;Length: 40/60/80mm;

Compatible guide wire: 0.035inch,Push rod length: 130cm;

por exemplo: H130060008035

Femoropopliteal artery stenosis

Diameter 3-6mm; length 40-220mm;

Compatível guide wire: {{0}}.035/0.018inch; push rod length: 130cm;

por exemplo:H130030015018,H130040015018

Inferior genicular artery stenosis

Diameter 1.5-4.0mm;conical balloon; length 20-220mm;

Compatible guide wire:{{0}}.035/0.018inch; push rod length: 150/180cm;

por exemplo:H150020015014,H150025015014


central vein

Diameter: 6-12mm; Length: 40/60/80/100mm

Compatible guide wire: 0.035 polegadas; push rod comprimento:130cm 

por exemplo:H130100004035,

H130120004035

PONTAS

Diâmetro:6/8 mm;Comprimento:60/80mm

Compatible guide wire:0.035 polegadas;push rod length:80cm

por exemplo:H080060008035

Modelos e especificações comuns

Recommended guidewire0.018″double lumen catheter 

Catheter length(cm)

Balloon diameter (milímetros)

Balloon Length(milímetros)

20

40

60

80

100

120

150

200

220

90

2.00

H090020002018D

H090020004018D

H090020006018D

H090020008018D

H090020010018D

H090020012018D

H090020015018D

-

-

2.50

H090025002018D

H090025004018D

H090025006018D

H090025008018D

H090025010018D

H090025012018D

H090025015018D

-

-

3.00

H090030002018D

H090030004018D

H090030006018D

H090030008018D

H090030010018D

H090030012018D

H090030015018D

-

-

3.50

H090035002018D

H090035004018D

H090035006018D

H090035008018D

H090035010018D

H090035012018D

H090035015018D

-

-

4.00

H090040002018D

H090040004018D

H090040006018D

H090040008018D

H090040010018D

H090040012018D

H090040015018D

H090040020018D

H090040022018D

5.00

H090050002018D

H090050004018D

H090050006018D

H090050008018D

H090050010018D

H090050012018D

H090050015018D

H090050020018D

H090050022018D

6.00

H090060002018D

H090060004018D

H090060006018D

H090060008018D

H090060010018D

H090060012018D

H090060015018D

H090060020018D

H090060022018D

7.00

H090070002018D

H090070004018D

H090070006018D

H090070008018D

H090070010018D

H090070012018D

H090070015018D

H090070020018D

H090070022018D

8.00

-

H090080004018D

H090080006018D

-

-

-

-

-

-

9.00

-

H090090004018D

H090090006018D

-

-

-

-

-

-

130

2.00

H130020002018D

H130020004018D

H130020006018D

H130020008018D

H130020010018D

H130020012018D

H130020015018D

-

-

2.50

H130025002018D

H130025004018D

H130025006018D

H130025008018D

H130025010018D

H130025012018D

H130025015018D

-

-

3.00

H130030002018D

H130030004018D

H130030006018D

H130030008018D

H130030010018D

H130030012018D

H130030015018D

-

-

3.50

H130035002018D

H130035004018D

H130035006018D

H130035008018D

H130035010018D

H130035012018D

H130035015018D

-

-

4.00

H130040002018D

H130040004018D

H130040006018D

H130040008018D

H130040010018D

H130040012018D

H130040015018D

H130040020018D

H130040022018D

5.00

H130050002018D

H130050004018D

H130050006018D

H130050008018D

H130050010018D

H130050012018D

H130050015018D

H130050020018D

H130050022018D

6.00

H130060002018D

H130060004018D

H130060006018D

H130060008018D

H130060010018D

H130060012018D

H130060015018D

H130060020018D

H130060022018D

7.00

H130070002018D

H130070004018D

H130070006018D

H130070008018D

H130070010018D

H130070012018D

H130070015018D

H130070020018D

H130070022018D

8.00

-

H130080004018D

H130080006018D

-

-

-

-

-

-

9.00

-

H130090004018D

H130090006018D

-

-

-

-

-

-

180

2.00

-

H180020004018D

H180020006018D

H180020008018D

H180020010018D

H180020012018D

H180020015018D

-

-

2.50

-

H180025004018D

H180025006018D

H180025008018D

H180025010018D

H180025012018D

H180025015018D

-

-

3.00

-

H180030004018D

H180030006018D

H180030008018D

H180030010018D

H180030012018D

H180030015018D

-

-

3.50

-

H180035004018D

H180035006018D

H180035008018D

H180035010018D

H180035012018D

H180035015018D

-

-

4.00

-

H180040004018D

H180040006018D

H180040008018D

H180040010018D

H180040012018D

H180040015018D

-

-

5.00

-

H180050004018D

H180050006018D

H180050008018D

H180050010018D

H180050012018D

H180050015018D

-

-

6.00

-

H180060004018D

H180060006018D

H180060008018D

H180060010018D

H180060012018D

-

-

-

7.00

-

H180070004018D

H180070006018D

H180070008018D

H180070010018D

H180070012018D

-

-

-


Vantagem do produto

  1. Comprimento do balão até 220 mm para o tratamento de lesões difusas das extremidades inferiores, reduzindo o número de obturações para o tratamento de lesões longas.

  2. Revestimento liso que reduz o atrito ao passar por lesões calcificadas